Connecting the display | ZM Series User Manual
Connecting power
3 421
1
2
3
4
5
6
+
-
1 Yellow Wire - power control
2 Blue wire - chassis ground
3 Red wire - positive DC supply (12V or 24V system)
4 Black wire - negative DC supply (12V or 24V system)
5 Fuse - see table at end of section
6 DC supply
¼ Note: this display is not intended for use vessels tted with a positive ground electrical
system. The power input cable screen drain wire should be connected to a negative ground.
¼ Note: chassis ground will typically not be required. In certain problematic installations it may
help stabilize touch screen sensitivity, ie. prevent ‘false’ touches, or non-registered touches.
Recommended fuse rating
Model ZM16-T ZM19-T
Fuse 3 amp 4 amp